摘要A combined detection system involving simultaneous LIF and contactless-conductometric measurements at the same place of the microfluidic chip was described. The LIF measurement was designed according to the confocal principle and a moveable contactless-conductivity detector was used in (CD)-D-4. Both measurements were mutually independent and advantageous in analyses of mixtures. Various experimental parameters affecting the response were examined and optimized. The performances were demonstrated by simultaneous detection of Rhodamine B. And the results showed that the combined detection system could be used sensitively and reliably. (C) 2008 Yong Yu. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.
关键词Microfluidic Chip Laser-induced Fluorescence (Lif) Capacitively Coupled Contactless-conductivity Detection ((Cd)-d-4) Microchip Capillary-electrophoresis Total Analysis Systems
DOI10.1016/j.cclet.2008.06.057
收录类别SCI
语种英语
WOS记录号WOS:000263323500020
关键词[WOS]MICROCHIP CAPILLARY-ELECTROPHORESIS ; TOTAL ANALYSIS SYSTEMS
WOS研究方向Chemistry
WOS类目Chemistry, Multidisciplinary
引用统计
被引频次:5[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://dspace.imech.ac.cn/handle/311007/25792
专题力学所知识产出(1956-2008)
通讯作者Yu, Y (reprint author), Chinese Acad Sci, Inst Mech, Natl Micrograv Lab, Beijing 100190, Peoples R China.
推荐引用方式
GB/T 7714
Shen F,Yang M,Yu Y,et al. Simultaneous Laser-Induced Fluorescence And Contactless-Conductivity Detection For Microfluidic Chip[J]. Chinese Chemical Letters = 中国化学快报(英文版),2008:1333-1336.
APA 申峰,Yang M,于泳,康琦,&Yu, Y .(2008).Simultaneous Laser-Induced Fluorescence And Contactless-Conductivity Detection For Microfluidic Chip.Chinese Chemical Letters = 中国化学快报(英文版),1333-1336.
MLA 申峰,et al."Simultaneous Laser-Induced Fluorescence And Contactless-Conductivity Detection For Microfluidic Chip".Chinese Chemical Letters = 中国化学快报(英文版) (2008):1333-1336.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Jp106.pdf(267KB) 开放获取--浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
Lanfanshu学术
Lanfanshu学术中相似的文章
[申峰]的文章
[Yang M]的文章
[于泳]的文章
百度学术
百度学术中相似的文章
[申峰]的文章
[Yang M]的文章
[于泳]的文章
必应学术
必应学术中相似的文章
[申峰]的文章
[Yang M]的文章
[于泳]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Jp106.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。