IMECH-IR  > 力学所知识产出(1956-2008)
Development Of Biosensor Based On Imaging Ellipsometry
Jin G(靳刚); Jin, G (reprint author), Chinese Acad Sci, Inst Mech, Beijing 100080, Peoples R China.
发表期刊Physica Status Solidi A-Applications And Materials Science
2008
页码810-816
ISSN1862-6300
摘要The concept of biosensor based on imaging ellipsometry was proposed ten years ago. Its principle and the methodology as well as some solutions to problems which have to be faced during the development are mentioned. Its properties of phase sensitive, high throughput and fast sampling, as well as label-free, sensitivity better than 1 ng/ml for Immunoglobulin G, and real-time analysis for protein interaction process, etc. provide a potential for applications in biomedicine field. The recent biosensing development with total internal reflection imaging ellipsometry is presented also. [GRAPHICS] An example of 48 protein arrays in matrix. (C) 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
关键词Bovine Serum-albumin Optical Protein-chip Neutralizing Antibody Silica Surfaces Immobilization Microarrays Interfaces Visualization Immunoassays Adsorption
DOI10.1002/pssa.200777810
收录类别SCI ; EI
语种英语
WOS记录号WOS:000255702600022
关键词[WOS]BOVINE SERUM-ALBUMIN ; OPTICAL PROTEIN-CHIP ; NEUTRALIZING ANTIBODY ; SILICA SURFACES ; IMMOBILIZATION ; MICROARRAYS ; INTERFACES ; VISUALIZATION ; IMMUNOASSAYS ; ADSORPTION
WOS研究方向Materials Science ; Physics
WOS类目Materials Science, Multidisciplinary ; Physics, Applied ; Physics, Condensed Matter
引用统计
被引频次:30[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://dspace.imech.ac.cn/handle/311007/26050
专题力学所知识产出(1956-2008)
通讯作者Jin, G (reprint author), Chinese Acad Sci, Inst Mech, Beijing 100080, Peoples R China.
推荐引用方式
GB/T 7714
Jin G,Jin, G . Development Of Biosensor Based On Imaging Ellipsometry[J]. Physica Status Solidi A-Applications And Materials Science,2008:810-816.
APA 靳刚,&Jin, G .(2008).Development Of Biosensor Based On Imaging Ellipsometry.Physica Status Solidi A-Applications And Materials Science,810-816.
MLA 靳刚,et al."Development Of Biosensor Based On Imaging Ellipsometry".Physica Status Solidi A-Applications And Materials Science (2008):810-816.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Jp235.pdf(527KB) 开放获取--浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
Lanfanshu学术
Lanfanshu学术中相似的文章
[靳刚]的文章
[Jin, G (reprint author), Chinese Acad Sci, Inst Mech, Beijing 100080, Peoples R China.]的文章
百度学术
百度学术中相似的文章
[靳刚]的文章
[Jin, G (reprint author), Chinese Acad Sci, Inst Mech, Beijing 100080, Peoples R China.]的文章
必应学术
必应学术中相似的文章
[靳刚]的文章
[Jin, G (reprint author), Chinese Acad Sci, Inst Mech, Beijing 100080, Peoples R China.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Jp235.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。