Improvement for sensitivity of biosensor with total internal reflection imaging ellipsometry (TIRIE) | |
Liu L(刘丽); Chen YY(陈艳艳); Meng YH(孟永宏); Chen S(陈涉); Jin G(靳刚); Jin, G (reprint author), Chinese Acad Sci, Natl Micrograv Lab, Inst Mech, 15 Bei Si Huan W Rd, Beijing 100190, Peoples R China | |
发表期刊 | Thin Solid Films |
2011 | |
卷号 | 519期号:9页码:2758-2762 |
ISSN | 0040-6090 |
摘要 | The biosensor based on the total internal reflection imaging ellipsometry (TIRIE) is realized as an automatic analysis method for protein interaction processes in real-time, with high throughput and label-free. An evanescent wave is used as the optical probe to monitor bio-molecular interactions on a chip surface with a high sensitivity due to its phase sensitive property. In this paper, the technique is optimized with a polarization setting, a spectroscopic light source and a low noise CCD detector to improve the performance of the biosensor in sensitivity and detection limit, as evidenced by a quantitative detection of Hepatitis B virus surface antigen (HbsAg) with concentrations of 8, 16, 32, 64, 125 and 250 ng/ml. The sensitivity is increased by one order of magnitude and the detection limit has been extended more than 50 times for HbsAg detection. (C) 2011 Elsevier B.V. All rights reserved. |
关键词 | Sensitivity Improvement Imaging Ellipsometry Total Internal Reflection Biosensor Hbsag Detection Plasmon Enhanced Ellipsometry Surface Resonance Sensors |
学科领域 | Materials Science ; Physics |
DOI | 10.1016/j.tsf.2010.12.130 |
URL | 查看原文 |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000289174200041 |
关键词[WOS] | PLASMON ENHANCED ELLIPSOMETRY ; SURFACE ; RESONANCE ; SENSORS |
WOS研究方向 | Materials Science ; Physics |
WOS类目 | Materials Science, Multidisciplinary ; Materials Science, Coatings & Films ; Physics, Applied ; Physics, Condensed Matter |
课题组名称 | NML纳米生物光学 |
论文分区 | 二类/Q2 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://dspace.imech.ac.cn/handle/311007/45100 |
专题 | 微重力重点实验室 |
通讯作者 | Jin, G (reprint author), Chinese Acad Sci, Natl Micrograv Lab, Inst Mech, 15 Bei Si Huan W Rd, Beijing 100190, Peoples R China |
推荐引用方式 GB/T 7714 | Liu L,Chen YY,Meng YH,et al. Improvement for sensitivity of biosensor with total internal reflection imaging ellipsometry (TIRIE)[J]. Thin Solid Films,2011,519,9,:2758-2762. |
APA | Liu L,Chen YY,Meng YH,Chen S,Jin G,&Jin, G .(2011).Improvement for sensitivity of biosensor with total internal reflection imaging ellipsometry (TIRIE).Thin Solid Films,519(9),2758-2762. |
MLA | Liu L,et al."Improvement for sensitivity of biosensor with total internal reflection imaging ellipsometry (TIRIE)".Thin Solid Films 519.9(2011):2758-2762. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
SCI-J2011168.pdf(612KB) | 开放获取 | -- | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论