| Surface plasmon resonance enhanced ellipsometric analysis for monitoring of cobalt electrochemical reaction in solution |
| Wang ZZ; Liu W(刘巍); Wang CX; Kan Q; Chen S(陈涉); Chen HD; Wang, CX (reprint author), Chinese Acad Sci, Inst Semicond, State Key Lab Integrated Optoelect, Beijing 100083, Peoples R China.
|
发表期刊 | SENSORS AND ACTUATORS B-CHEMICAL
|
| 2013-05-01
|
卷号 | 181页码:221-226 |
ISSN | 0925-4005
|
摘要 | Cobalt-based ion selective electrode (ISE) is one of the key methods for phosphate detection. In this paper, surface plasmon resonance (SPR) enhanced ellipsometric analysis method has been used to monitor the electrochemical reaction process at Co ISE sensor surface and the mass consumption of sensitive electrode membranes. An Au-Co bilayer film is designed as optical detection interface. In order to obtain detectable reflection intensity variation with Co thickness, Au film and Co film thickness are optimized at TM polarization state. According to the calculation results, 50 nm Au film is formed on glass substrate by electron beam evaporation. Then cobalt film with thickness of about 20 nm is grown on gold film by electrochemical deposition method. Ellipsometric measurements were performed at SPR angle 59. The consuming process of Co film reacting with dissolved oxygen in deionized water has been obtained by monitoring the change of reflection intensity. |
关键词 | Surface Plasmon Resonance
Ellipsometry
Ion Selective Electrode
Image Contrast
|
学科领域 | 交叉与边缘领域的力学
|
URL | 查看原文
|
收录类别 | SCI
; EI
|
语种 | 英语
|
WOS记录号 | WOS:000317941100032
|
项目资助者 | National Basic Research of China [2009CB320300, 2010CB934104, 2011CB933203, 2011CB933102]; Nation Natural Foundation of China [61036009, 60978067]
|
课题组名称 | LHD微尺度和非平衡流动
|
论文分区 | 二类/Q1
|
引用统计 |
|
文献类型 | 期刊论文
|
条目标识符 | http://dspace.imech.ac.cn/handle/311007/47259
|
专题 | 微重力重点实验室
|
通讯作者 | Wang, CX (reprint author), Chinese Acad Sci, Inst Semicond, State Key Lab Integrated Optoelect, Beijing 100083, Peoples R China. |
推荐引用方式 GB/T 7714 |
Wang ZZ,Liu W,Wang CX,et al. Surface plasmon resonance enhanced ellipsometric analysis for monitoring of cobalt electrochemical reaction in solution[J]. SENSORS AND ACTUATORS B-CHEMICAL,2013,181:221-226.
|
APA |
Wang ZZ.,刘巍.,Wang CX.,Kan Q.,陈涉.,...&Wang, CX .(2013).Surface plasmon resonance enhanced ellipsometric analysis for monitoring of cobalt electrochemical reaction in solution.SENSORS AND ACTUATORS B-CHEMICAL,181,221-226.
|
MLA |
Wang ZZ,et al."Surface plasmon resonance enhanced ellipsometric analysis for monitoring of cobalt electrochemical reaction in solution".SENSORS AND ACTUATORS B-CHEMICAL 181(2013):221-226.
|
修改评论