A Microfluidic-Based Multi-Shear Device for Investigating the Effects of Low Fluid-Induced Stresses on Osteoblasts | |
Yu, WL; Qu, H; Hu GQ(胡国庆); Zhang, Q; Song, K; Guan, HJ; Liu, TJ; Qin, JH; Liu, TJ (reprint author), Dalian Med Univ, Coll Stomatol, Sect Oral Pathol, Dalian, Peoples R China. | |
发表期刊 | PLOS ONE |
2014-02-27 | |
卷号 | 9期号:2页码:e89966 |
ISSN | 1932-6203 |
摘要 | Interstitial fluid flow (IFF) within the extracellular matrix (ECM) produces low magnitude shear stresses on cells. Fluid flow-induced stress (FSS) plays an important role during tissue morphogenesis. To investigate the effect of low FSS generated by IFF on cells, we developed a microfluidic-based cell culture device that can generate multiple low shear stresses. By changing the length and width of the flow-in channels, different continuous low level shear stresses could be generated in individual cell culture chambers. Numerical calculations demonstrate uniform shear stress distributions of the major cell culture area of each chamber. This calculation is further confirmed by the wall shear stress curves. The effects of low FSS on MC3T3-E1 proliferation and differentiation were studied using this device. It was found that FSS ranging from 1.5 to 52.6 mu Pa promoted MC3T3-E1 proliferation and differentiation, but FSS over 412 mu Pa inhibited the proliferation and differentiation of MC3T3-E1 cells. FSS ranging from 1.5 to 52.6 mu Pa also increased the expression of Runx2, a key transcription factor regulating osteoblast differentiation. It is suggested that Runx2 might be an important regulator in low FSS-induced MC3T3-E1 differentiation. This device allows for detailed study of the effect of low FSS on the behaviors of cells; thus, it would be a useful tool for analysis of the effects of IFF-induced shear stresses on cells. |
关键词 | Elasto-plastic-damage Behavior Anisotropy Physical Mechanism Finite Deformation Constitutive Theory Component Assembling Model |
学科领域 | Science & Technology - Other Topics |
URL | 查看原文 |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000332390800061 |
项目资助者 | This work was supported by National Natural Science Foundation of China (No. 81171425) and Program for Liaoning Excellent Talents in University (No. LR201013). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. |
课题组名称 | LNM微纳米流体力学 |
论文分区 | 二类/Q1 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://dspace.imech.ac.cn/handle/311007/48765 |
专题 | 非线性力学国家重点实验室 |
通讯作者 | Liu, TJ (reprint author), Dalian Med Univ, Coll Stomatol, Sect Oral Pathol, Dalian, Peoples R China. |
推荐引用方式 GB/T 7714 | Yu, WL,Qu, H,Hu GQ,et al. A Microfluidic-Based Multi-Shear Device for Investigating the Effects of Low Fluid-Induced Stresses on Osteoblasts[J]. PLOS ONE,2014,9,2,:e89966. |
APA | Yu, WL.,Qu, H.,Hu GQ.,Zhang, Q.,Song, K.,...&Liu, TJ .(2014).A Microfluidic-Based Multi-Shear Device for Investigating the Effects of Low Fluid-Induced Stresses on Osteoblasts.PLOS ONE,9(2),e89966. |
MLA | Yu, WL,et al."A Microfluidic-Based Multi-Shear Device for Investigating the Effects of Low Fluid-Induced Stresses on Osteoblasts".PLOS ONE 9.2(2014):e89966. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
IMCAS-J2014-061.pdf(4089KB) | 开放获取 | -- | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论