Improved Potentiometric and Optic Sensitivity of Polyaniline Film to Dissolved Oxygen by Incorporating Iron-Porphyrin | |
Li M(李萌); Ornelas IM; Liu W(刘巍); Niu Y(牛宇); Correia JP; Viana AS; Jin G(靳刚); Jin, G (reprint author), Chinese Acad Sci, NML, Inst Mech, 15 Bei Si Huan West Rd, Beijing 100190, Peoples R China. | |
发表期刊 | ELECTROANALYSIS |
2015-06 | |
卷号 | 27期号:6页码:1427-1435 |
ISSN | 1040-0397 |
摘要 | Polyaniline (PAn) films can be used in an electrochemical and optical combination system to amplify the optical signal for dissolved oxygen (DO) detection. To further improve the sensitivity of PAn film to DO, an oxygen-sensitive molecule, Fe(III) meso-tetera (4-sulfonatophenyl) porphyrin (FeTSPP) is incorporated into PAn during the film generation. Results show that, after incorporating FeTSPP into the PAn matrix, both optical and potentiometric responses to DO are improved. The optimal optical signal is obtained under the application of -2.5 mu A to the modified electrode. Under this applied current, both optical and potentiometric signals show linear relations with the DO concentration within the range of 0.00-4.63 mgL(-1), and the sensitivities for optical and potentiometric signals are 4.18 grayscale units mg(-1)L and 13.39 mVmg(-1) L, respectively. |
关键词 | Dissolved Oxygen Electrochemical And Optical Combination Sensor Fe(Iii) Meso-tetra (4-sulfonatophenyl) Porphyrin (Fetspp) Polyaniline Total Internal Reflection Imaging Ellipsometry(Tirie) |
DOI | 10.1002/elan.201400678 |
URL | 查看原文 |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000356604300013 |
WOS研究方向 | Chemistry ; Electrochemistry |
WOS类目 | Chemistry, Analytical ; Electrochemistry |
项目资助者 | National Basic Research Program of China [2009CB320302] ; National High Technology Research Development Program of China [2008AA02Z419] ; International Science & Technology Cooperation Program of China [2012DFG31880] ; Projects of Sino-Portugal S&T Cooperation, Fundacao para a Ciencia e a Tecnologia [PTDC/QUI-QUI/121857/2010] ; National Natural Science Foundation of China [21305147] ; Instrument Developing Project of the Chinese Academy of Sciences [KJCX2-YW-M04, KJCX2-YW-M03] |
课题组名称 | NML纳米生物光学 |
论文分区 | 二类/Q2 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://dspace.imech.ac.cn/handle/311007/54969 |
专题 | 微重力重点实验室 |
通讯作者 | Jin, G (reprint author), Chinese Acad Sci, NML, Inst Mech, 15 Bei Si Huan West Rd, Beijing 100190, Peoples R China. |
推荐引用方式 GB/T 7714 | Li M,Ornelas IM,Liu W,et al. Improved Potentiometric and Optic Sensitivity of Polyaniline Film to Dissolved Oxygen by Incorporating Iron-Porphyrin[J]. ELECTROANALYSIS,2015,27,6,:1427-1435. |
APA | Li M.,Ornelas IM.,Liu W.,Niu Y.,Correia JP.,...&Jin, G .(2015).Improved Potentiometric and Optic Sensitivity of Polyaniline Film to Dissolved Oxygen by Incorporating Iron-Porphyrin.ELECTROANALYSIS,27(6),1427-1435. |
MLA | Li M,et al."Improved Potentiometric and Optic Sensitivity of Polyaniline Film to Dissolved Oxygen by Incorporating Iron-Porphyrin".ELECTROANALYSIS 27.6(2015):1427-1435. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Li-2015-Improved.pdf(2588KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |