Research on a quantitative method for three-dimensional computed tomography of chemiluminescence | |
Zhou GX(周功喜)1,2; Li F(李飞)2; Wang KL(王宽亮)3; Lin X(林鑫)2; Yu XL(余西龙)2 | |
发表期刊 | APPLIED OPTICS |
2020-06-10 | |
卷号 | 59期号:17页码:5310-5318 |
ISSN | 1559-128X |
摘要 | To develop a more advanced 3D computed tomography of the chemiluminescence method, the first quantitative 3D diagnosis was realized. The nonlinearity coefficient, the nonuniformity coefficient of the camera response, and various optical fiber attenuation coefficients were obtained through correction experiments. The conversion relationship between the number of photons released by the target object per unit time and the camera gray value at a specified solid angle was also calibrated. To verify the quantitative reconstruction equation, 3D reconstructions of a methane-air flat flame and a simulated phantom were performed for comparison. The method can overcome artificial distortions caused by uncorrected reconstruction. (C) 2020 Optical Society of America |
DOI | 10.1364/AO.393225 |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000540285800053 |
关键词[WOS] | CHARGE-COUPLED-DEVICE ; FLAME MEASUREMENTS ; COMBUSTION ; KHZ ; RECONSTRUCTION ; VALIDATION ; CCD |
WOS研究方向 | Optics |
WOS类目 | Optics |
项目资助者 | National Natural Science Foundation of China[11372329] ; National Natural Science Foundation of China[11802315] ; National Natural Science Foundation of China[11927803] ; Youth Innovation Promotion Association of the Chinese Academy of Sciences[2018023] |
论文分区 | Q3 |
力学所作者排名 | 1 |
RpAuthor | Li, Fei |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://dspace.imech.ac.cn/handle/311007/84767 |
专题 | 高温气体动力学国家重点实验室 |
作者单位 | 1.Univ Chinese Acad Sci, Sch Engn Sci, Beijing 100049, Peoples R China; 2.Chinese Acad Sci, State Key Lab High Temp Gas Dynam, Inst Mech, Beijing 100190, Peoples R China; 3.Beijing Inst Technol, Sch Aerosp Engn, Beijing 100081, Peoples R China |
推荐引用方式 GB/T 7714 | Zhou GX,Li F,Wang KL,et al. Research on a quantitative method for three-dimensional computed tomography of chemiluminescence[J]. APPLIED OPTICS,2020,59,17,:5310-5318. |
APA | 周功喜,李飞,王宽亮,林鑫,&余西龙.(2020).Research on a quantitative method for three-dimensional computed tomography of chemiluminescence.APPLIED OPTICS,59(17),5310-5318. |
MLA | 周功喜,et al."Research on a quantitative method for three-dimensional computed tomography of chemiluminescence".APPLIED OPTICS 59.17(2020):5310-5318. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Jp2020211.pdf(2054KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
Lanfanshu学术 |
Lanfanshu学术中相似的文章 |
[周功喜]的文章 |
[李飞]的文章 |
[王宽亮]的文章 |
百度学术 |
百度学术中相似的文章 |
[周功喜]的文章 |
[李飞]的文章 |
[王宽亮]的文章 |
必应学术 |
必应学术中相似的文章 |
[周功喜]的文章 |
[李飞]的文章 |
[王宽亮]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论