IMECH-IR  > 微重力重点实验室
An Imaging Ellipsometry Approach to Dissolved Oxygen Measurement on Surface Tethered Weak Polyelectrolyte Modified Electrode
Liu W(刘巍); Li M(李萌); Lv B; Chen YY; Ma HW; Viana AS; Correia JP; Jin G(靳刚); Jin, G (reprint author), Chinese Acad Sci, Inst Mech, NML, Beijing 100190, Peoples R China.
发表期刊JOURNAL OF THE ELECTROCHEMICAL SOCIETY
2016
卷号163期号:5页码:H286-H291
ISSN0013-4651
摘要Electro - total internal reflection ellipsometry has been reported as a phase sensitive ellipsometry technique to observe the redox reactions on the surface of the electrode. In this work, with the imaging ellipsometry, we have used Electro-total internal reflection imaging ellipsometry (Electro-TIRIE) to measure the dissolved oxygen concentration on the surface tethered weak polyelectrolyte brush, carboxylated poly(oligo(ethylene glycol) methacrylate-random-2-hydroxyethylmethacrylate), modified electrode. The cyclic voltammetry has shown despite the covering of the weak polyelectrolyte brush, the electrode could still reduce the dissolved oxygen and Electro-TIRIE technique could unveil the different swelling behavior of the brushes during the reduction. The difference may be attributed to the electro-active probe permeability of the brushes. With the imaging ellipsometry, we proposed a parallel dissolved oxygen measurement. Compared with our previous results, the optical signal noise ratio has been enhanced 10 times and the measurement time has reduced from 30 minutes to 10 minutes. (C) 2016 The Electrochemical Society. All rights reserved.
DOI10.1149/2.0331605jes
URL查看原文
收录类别SCI
语种英语
WOS记录号WOS:000370866700107
关键词[WOS]MATRIX COMPOSITES ; MECHANICAL-PROPERTIES ; FRACTURE-TOUGHNESS ; PLASTICITY ; DEFORMATION ; BEHAVIOR ; STRENGTH ; COMPRESSION ; INSTABILITY ; EVOLUTION
WOS研究方向Electrochemistry ; Materials Science
WOS类目Electrochemistry ; Materials Science, Coatings & Films
项目资助者The authors acknowledge the financial support to the National Natural Science Foundation of China (21305147, 11274345), to the International Science & Technology Cooperation Program of China (2015DFG32390), FCT project-UID/MULTI/00612/2013 to the National Basic Research Program of China (2009CB320302), to the National High Technology Research Development Program of China (2008AA02Z419), and to the Instrument Developing Project of the Chinese Academy of Sciences (KJCX2-YW-M04, KJCX2-YW-M03).
课题组名称NML纳米生物光学
论文分区一类
力学所作者排名True
引用统计
被引频次:4[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://dspace.imech.ac.cn/handle/311007/58661
专题微重力重点实验室
通讯作者Jin, G (reprint author), Chinese Acad Sci, Inst Mech, NML, Beijing 100190, Peoples R China.
推荐引用方式
GB/T 7714
Liu W,Li M,Lv B,et al. An Imaging Ellipsometry Approach to Dissolved Oxygen Measurement on Surface Tethered Weak Polyelectrolyte Modified Electrode[J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY,2016,163,5,:H286-H291.
APA Liu W.,Li M.,Lv B.,Chen YY.,Ma HW.,...&Jin, G .(2016).An Imaging Ellipsometry Approach to Dissolved Oxygen Measurement on Surface Tethered Weak Polyelectrolyte Modified Electrode.JOURNAL OF THE ELECTROCHEMICAL SOCIETY,163(5),H286-H291.
MLA Liu W,et al."An Imaging Ellipsometry Approach to Dissolved Oxygen Measurement on Surface Tethered Weak Polyelectrolyte Modified Electrode".JOURNAL OF THE ELECTROCHEMICAL SOCIETY 163.5(2016):H286-H291.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
a2016-111.pdf(929KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
Lanfanshu学术
Lanfanshu学术中相似的文章
[Liu W(刘巍)]的文章
[Li M(李萌)]的文章
[Lv B]的文章
百度学术
百度学术中相似的文章
[Liu W(刘巍)]的文章
[Li M(李萌)]的文章
[Lv B]的文章
必应学术
必应学术中相似的文章
[Liu W(刘巍)]的文章
[Li M(李萌)]的文章
[Lv B]的文章
相关权益政策
暂无数据
收藏/分享
文件名: a2016-111.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。