IMECH-IR  > 微重力重点实验室
Soluble Angiopoietin Receptor Tie-2 In Patients With Acute Myocardial Infarction And Its Detection By Optical Protein-Chip
Wang CL; Li JQ; Li HW; Jin G(靳刚); Wang ZH(王战会); Meng YH(孟永宏); Xiu RJ
发表期刊Artificial Cells Blood Substitutes and Biotechnology
2009
卷号37期号:4页码:183-186
ISSN1073-1199
摘要The Tie-2 receptor has been shown to play a role in angiogenesis in atherosclerosis. The conventional method assaying the level of soluble Tie-2 (sTie-2) was ELISA. However, this method has some disadvantages. The aims of this research are to establish a more simple detection method, the optical protein-chip based on imaging ellipsomtry (OPC-IE) applying to Tie-2 assay. The sTie-2 biosensor surface on silicon wafer was prepared first, and then serum levels of sTie-2 in 38 patients with AMI were measured on admission (day 1), day 2, day 3 and day 7 after onset of chest pain and 41 healthy controls by ELISA and OPC-IE in parallel. Median level of sTie-2 increased significantly in the AMI patients when compared with the controls. Statistics showed there was a significant correlation in sTie-2 results between the two methods (r=0.923, P0.01). The result of this study showed that the level of sTie-2 increased in AMI, and OPC-IE assay was a fast, reliable, and convenient technique to measure sTie-2 in serum.
关键词Soluble Tie-2 Acute Myocardial Infarction Elisa Optical Protein-chip Imaging Ellipsometry Imaging Ellipsometry Tyrosine Kinase Tek
DOI10.1080/10731190903043416
URL查看原文
收录类别SCI
语种英语
WOS记录号WOS:000267835500007
关键词[WOS]IMAGING ELLIPSOMETRY ; TYROSINE KINASE ; TEK
WOS研究方向Biotechnology & Applied Microbiology ; Engineering ; Materials Science
WOS类目Biotechnology & Applied Microbiology ; Engineering, Biomedical ; Materials Science, Biomaterials
引用统计
被引频次:2[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://dspace.imech.ac.cn/handle/311007/26690
专题微重力重点实验室
通讯作者Wang CL
推荐引用方式
GB/T 7714
Wang CL,Li JQ,Li HW,et al. Soluble Angiopoietin Receptor Tie-2 In Patients With Acute Myocardial Infarction And Its Detection By Optical Protein-Chip[J]. Artificial Cells Blood Substitutes and Biotechnology,2009,37,4,:183-186.
APA Wang CL.,Li JQ.,Li HW.,Jin G.,Wang ZH.,...&Xiu RJ.(2009).Soluble Angiopoietin Receptor Tie-2 In Patients With Acute Myocardial Infarction And Its Detection By Optical Protein-Chip.Artificial Cells Blood Substitutes and Biotechnology,37(4),183-186.
MLA Wang CL,et al."Soluble Angiopoietin Receptor Tie-2 In Patients With Acute Myocardial Infarction And Its Detection By Optical Protein-Chip".Artificial Cells Blood Substitutes and Biotechnology 37.4(2009):183-186.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
GZ11001719.pdf(89KB) 开放获取--浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
Lanfanshu学术
Lanfanshu学术中相似的文章
[Wang CL]的文章
[Li JQ]的文章
[Li HW]的文章
百度学术
百度学术中相似的文章
[Wang CL]的文章
[Li JQ]的文章
[Li HW]的文章
必应学术
必应学术中相似的文章
[Wang CL]的文章
[Li JQ]的文章
[Li HW]的文章
相关权益政策
暂无数据
收藏/分享
文件名: GZ11001719.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。