A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for non-uniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS scheme is used to implement the wavelength-multiplexed-profile fitting method. Second harmonic (2f) signal of eight H2O transitions features near 7,170 cm(-1) are measured in one period using a single tunable diode laser. Spatial resolved temperature distribution upon a CH4/air premixed flat flame burner is obtained. The result validates the feasibility of strategy for non-uniform flow field diagnostics by means of WMS-2f TDLAS.
Yu XL,Li F,Chen LH,et al. Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser[J]. Acta Mechanica Sinica,2010,26,1,:147-149.
APA
余西龙,Li F,陈立红,张新宇,&Yu XL.(2010).Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser.Acta Mechanica Sinica,26(1),147-149.
MLA
余西龙,et al."Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser".Acta Mechanica Sinica 26.1(2010):147-149.