IMECH-IR  > 微重力重点实验室
Detection of alpha-fetoprotein through biological signal amplification by biosensor based on imaging ellipsometry
Huang CH; Chen YY(陈艳艳); Wang CX; Zhu W(朱伟); Ma HW; Jin G(靳刚); Chen, YY (reprint author), Chinese Acad Sci, Suzhou Inst Nanotech & Nanobion, Suzhou, Peoples R China
会议录名称THIN SOLID FILMS
2011
页码2763-2767
会议名称5th International Conference on Spectroscopic Ellipsometry
会议日期MAY 23-29, 2010
会议地点Albany, NY
摘要High sensitive and quantitative detection of alpha-fetoprotein (AFP) by biosensor based on imaging ellipsometry (BIE) through biological amplification was investigated. AFP firstly reacted with the rat monoclonal antibody (rat-mAb) initially immobilized on glutaraldehyde modified silicon surface, then rabbit anti-human AFP polyclonal antibodies (Rabbit-pAb) and goat anti-rabbit IgG (goat-IgG) were sequentially applied to amplify signal. Results revealed that signal was enhanced approximately six fold. The linear range of AFP detection was 20.0-200.0 ng/ml with a low limit of 5.0 ng/ml (S/N = 3). The cross-reaction rate was less than 5.2% evaluated by biomarker (carcinoembryonic antigen, carbohydrate 19-9 and carbohydrate antigen 242) and two common proteins (human serum albumin, fibrinogen) and their mixture. Coefficient variation (CV) for intra-slide and inter-slide reproducibility were 10.3%, 6.6%, 6.3% and 10.7%, 7.9%, 6.4% for 41.6 ng/ml, 83.2 ng/ml and 128.4 ng/ml AFP. In clinic application, cut-off value at 28.6 ng/ml was also determined with sensitivity 0.72 and specificity 0.94. Results of 47 clinic patient samples detected by BIE were in good agreement with those of electrochemiluminescence immunoassay (ECLIA) (R2 = 0.9949). The area under receiver operating characteristic curve (ROC) curve is 0.89. Statistical analysis showed that BIE is high agreement with ECLIA (Kappa = 0.733, U = 3.21>U0.01). It shows a potential for hepatocellular carcinoma (HCC) diagnosis. (C) 2010 Elsevier B.V. All rights reserved.
关键词Imaging Ellipsometry Biosensor Signal Amplification Alpha-fetoprotein Hepatocellular Carcinoma Protein Microarrays Visualization Prospects Cancer Serum
课题组名称中科院国家微重力实验室
资助信息Univ Albany, Coll Nanoscale & Engn
URL查看原文
收录类别CPCI(ISTP)
语种英语
文献类型会议论文
条目标识符http://dspace.imech.ac.cn/handle/311007/45316
专题微重力重点实验室
通讯作者Chen, YY (reprint author), Chinese Acad Sci, Suzhou Inst Nanotech & Nanobion, Suzhou, Peoples R China
推荐引用方式
GB/T 7714
Huang CH,Chen YY,Wang CX,et al. Detection of alpha-fetoprotein through biological signal amplification by biosensor based on imaging ellipsometry[C]THIN SOLID FILMS,2011:2763-2767.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Conf2011-087.pdf(572KB) 开放获取--浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
Lanfanshu学术
Lanfanshu学术中相似的文章
[Huang CH]的文章
[陈艳艳]的文章
[Wang CX]的文章
百度学术
百度学术中相似的文章
[Huang CH]的文章
[陈艳艳]的文章
[Wang CX]的文章
必应学术
必应学术中相似的文章
[Huang CH]的文章
[陈艳艳]的文章
[Wang CX]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Conf2011-087.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。