Detection of alpha-fetoprotein through biological signal amplification by biosensor based on imaging ellipsometry | |
Huang CH; Chen YY(陈艳艳); Wang CX; Zhu W(朱伟); Ma HW; Jin G(靳刚); Chen, YY (reprint author), Chinese Acad Sci, Suzhou Inst Nanotech & Nanobion, Suzhou, Peoples R China | |
会议录名称 | THIN SOLID FILMS |
2011 | |
页码 | 2763-2767 |
会议名称 | 5th International Conference on Spectroscopic Ellipsometry |
会议日期 | MAY 23-29, 2010 |
会议地点 | Albany, NY |
摘要 | High sensitive and quantitative detection of alpha-fetoprotein (AFP) by biosensor based on imaging ellipsometry (BIE) through biological amplification was investigated. AFP firstly reacted with the rat monoclonal antibody (rat-mAb) initially immobilized on glutaraldehyde modified silicon surface, then rabbit anti-human AFP polyclonal antibodies (Rabbit-pAb) and goat anti-rabbit IgG (goat-IgG) were sequentially applied to amplify signal. Results revealed that signal was enhanced approximately six fold. The linear range of AFP detection was 20.0-200.0 ng/ml with a low limit of 5.0 ng/ml (S/N = 3). The cross-reaction rate was less than 5.2% evaluated by biomarker (carcinoembryonic antigen, carbohydrate 19-9 and carbohydrate antigen 242) and two common proteins (human serum albumin, fibrinogen) and their mixture. Coefficient variation (CV) for intra-slide and inter-slide reproducibility were 10.3%, 6.6%, 6.3% and 10.7%, 7.9%, 6.4% for 41.6 ng/ml, 83.2 ng/ml and 128.4 ng/ml AFP. In clinic application, cut-off value at 28.6 ng/ml was also determined with sensitivity 0.72 and specificity 0.94. Results of 47 clinic patient samples detected by BIE were in good agreement with those of electrochemiluminescence immunoassay (ECLIA) (R2 = 0.9949). The area under receiver operating characteristic curve (ROC) curve is 0.89. Statistical analysis showed that BIE is high agreement with ECLIA (Kappa = 0.733, U = 3.21>U0.01). It shows a potential for hepatocellular carcinoma (HCC) diagnosis. (C) 2010 Elsevier B.V. All rights reserved. |
关键词 | Imaging Ellipsometry Biosensor Signal Amplification Alpha-fetoprotein Hepatocellular Carcinoma Protein Microarrays Visualization Prospects Cancer Serum |
课题组名称 | 中科院国家微重力实验室 |
资助信息 | Univ Albany, Coll Nanoscale & Engn |
URL | 查看原文 |
收录类别 | CPCI(ISTP) |
语种 | 英语 |
文献类型 | 会议论文 |
条目标识符 | http://dspace.imech.ac.cn/handle/311007/45316 |
专题 | 微重力重点实验室 |
通讯作者 | Chen, YY (reprint author), Chinese Acad Sci, Suzhou Inst Nanotech & Nanobion, Suzhou, Peoples R China |
推荐引用方式 GB/T 7714 | Huang CH,Chen YY,Wang CX,et al. Detection of alpha-fetoprotein through biological signal amplification by biosensor based on imaging ellipsometry[C]THIN SOLID FILMS,2011:2763-2767. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Conf2011-087.pdf(572KB) | 开放获取 | -- | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论