IMECH-IR  > 非线性力学国家重点实验室
Effect of the number of projections in X-ray CT imaging on image quality and digital volume correlation measurement
Zhang, Xuanhao1; Sun LJ(孙立娟)2; Wang, Bo1; Pan, Bing1
Corresponding AuthorPan, Bing(panb@buaa.edu.cn)
Source PublicationMEASUREMENT
2022-05-15
Volume194Pages:12
ISSN0263-2241
AbstractDigital volume correlation (DVC) quantifies internal 3D displacement and strain fields by correlating the volume images of a tested object acquired at different states. When using X-ray CT-based DVC, the number of projections is a key parameter that affects the acquisition time and quality of reconstructed volumetric images, and therefore the precision and temporal resolutions of DVC measurement. More projections result in high-quality volume images for DVC calculation but longer acquisition time and pronounced thermal drifts of the X-ray source. Few projections lead to quicker acquisition and fewer thermal drifts, but may degrade image quality and thus induce larger DVC measurement errors. Selecting an appropriate number of projections during CT imaging is therefore of practical significance for DVC measurement. To solve this dilemma, the effect of the number of projections on DVC measurements with X-ray CT is experimentally investigated in this work. First, numerically simulated speckle volume images with different numbers of projections were reconstructed by using FDK (Feldkamp) al-gorithm, and the influence of the number of projections on DVC measurement was analyzed. Then, real rescan and compression experiments performed on a copper foam sample were carried out to further study the effect of projection number on DVC measurements. Both simulation and real experiments show that more projections result in longer imaging time but higher quality volume image and DVC measurement. DVC measurement errors decrease with the increase of projections at different decline rates. Therefore, an appropriate number of pro-jections can be specified based on the results according to the requirements of DVC measurement precision and temporal resolution. For the specific X-ray CT device used in this real compression experiment, 36 ~ 60 pro-jections are suggested to balance measurement precision and temporal resolution, and more than 720 projections are necessary for pursuing higher accuracy.
KeywordDigital volume correlation Number of projections X-ray computed tomography FDK algorithm
DOI10.1016/j.measurement.2022.111061
Indexed BySCI ; EI
Language英语
WOS IDWOS:000793176700002
WOS KeywordTOMOGRAPHY ; STRAIN
WOS Research AreaEngineering ; Instruments & Instrumentation
WOS SubjectEngineering, Multidisciplinary ; Instruments & Instrumentation
Funding ProjectNational Natural Science Foundation of China[11925202] ; National Natural Science Foundation of China[11872009]
Funding OrganizationNational Natural Science Foundation of China
Classification二类/Q1
Ranking2
ContributorPan, Bing
Citation statistics
Cited Times:5[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://dspace.imech.ac.cn/handle/311007/89352
Collection非线性力学国家重点实验室
Affiliation1.Beihang Univ, Inst Solid Mech, Beijing 100191, Peoples R China;
2.Chinese Acad Sci, Inst Mech, Beijing 100190, Peoples R China
Recommended Citation
GB/T 7714
Zhang, Xuanhao,Sun LJ,Wang, Bo,et al. Effect of the number of projections in X-ray CT imaging on image quality and digital volume correlation measurement[J]. MEASUREMENT,2022,194:12.
APA Zhang, Xuanhao,孙立娟,Wang, Bo,&Pan, Bing.(2022).Effect of the number of projections in X-ray CT imaging on image quality and digital volume correlation measurement.MEASUREMENT,194,12.
MLA Zhang, Xuanhao,et al."Effect of the number of projections in X-ray CT imaging on image quality and digital volume correlation measurement".MEASUREMENT 194(2022):12.
Files in This Item: Download All
File Name/Size DocType Version Access License
Jp2022FA368_2022_Eff(6196KB)期刊论文出版稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Lanfanshu
Similar articles in Lanfanshu
[Zhang, Xuanhao]'s Articles
[孙立娟]'s Articles
[Wang, Bo]'s Articles
Baidu academic
Similar articles in Baidu academic
[Zhang, Xuanhao]'s Articles
[孙立娟]'s Articles
[Wang, Bo]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Zhang, Xuanhao]'s Articles
[孙立娟]'s Articles
[Wang, Bo]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Jp2022FA368_2022_Effect of the number of projections in X-ray CT imaging on image quality and.pdf
Format: Adobe PDF
This file does not support browsing at this time
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.